UM 300 Patient Monitor
UM 300 is a multi-parameter portable patient monitor with 12 '' color display and enhanced network capacity. UM 300 Patient Monitor is ideal for operating rooms, intensive care units, recovery rooms and patient care during transport. Monitor can be connected to the Central Station to make monitoring information available throughout the hospital.
- • Unique networking capacity which allows viewing hospital network data, digital images, lab results, medication guidelines, bed-to-bed viewing etc;
- • High brightness, wide viewing angle, colour 12.1'' display;
- • Expanded monitoring capabilities: ECG, HR, pulse oximetry, NIBP, respiration rate, temperature, invasive blood pressure, cardiac output, CO2, N2O, O2 and 5 anesthetic agents;
- • Simultaneous display of up to 10 real-time waveforms;
- • Two modes of numerics visualization – Standard and Large Numbers;
- • Advanced digital signal processing;
- • Alarm supervision of all vital signs;
- • Multi-level alarm management;
- • 12-lead ECG;
- • Arrhythmia and ST segment analysis;
- • Heart rate variability analysis;
- • Up to 240 hours trend for all measured values;
- • 60 seconds full-disclosure waveforms review;
- • Up to 4 hours of internal battery operation;
- • Drug dose and infusion rate calculator;
- • Touch screen and rotary knob control;
- • Remote access to patient information using mobile phone, PC or PDA;
- • UniPort connectors automatically detect the type of connected sensor.
|
DISPLAY
|
|
Size:
|
12.1'' / 30.7 cm diagonal
|
|
Type:
|
bright colour TFT
|
|
Resolution:
|
800x600 dots
|
|
Number of traces:
|
up to 10, user selectable
|
|
ECG
|
|
Leads:
|
I, II, III, aVR, aVL, aVF, V1-V6
|
|
Sweep Speed:
|
6.25; 12.5; 25 и 50 mm/s
|
|
Sensitivity:
Arrhythmia analysis
|
5; 10; 20; 40 mm/mV, AUTO
|
|
|
|
|
Defibrillator protection
|
|
Pacemaker detection
|
|
|
|
|
|
HEART RATE
|
|
Range:
|
15 -350 BPM
|
|
Resolution:
|
1 BPM
|
|
Accuracy:
|
± 1 BPM
|
|
|
|
|
|
|
|
SpO2
|
|
Range:
|
0 -100%
|
|
Resolution:
|
1%
|
|
Accuracy:
|
± 2% (70-100%) 3% (40-70%)
|
|
Pulse rate range:
|
15 - 350 BPM
|
|
Probes:
|
Adult, neonatal
|
|
Accuracy:
|
± 2 BPM
|
|
TEMPERATURE
|
|
Number of channels:
|
1 or 2
|
|
Range:
|
0 - 45°C
|
|
Accuracy:
|
± 0.1°C (30-42 C)
|
|
Probes:
|
YSI 400 (Rectal, skin)
|
|
RESPIRATION RATE
|
|
Method:
|
Impedance
|
|
Range:
|
0-150 1/min
|
|
Accuracy:
|
± 1/min
|
|
Apnea time interval
|
5-40 sec
|
|
Pneumogram visualization
|
|
|
NIBP
|
|
Method:
|
Oscillometric
|
|
Range:
|
0 - 300 mmHg (adult), 0 - 150 mmHg (neonatal)
|
|
Modes:
|
Manual, automatic, STAT
|
|
Cuff:
|
Adult, pediatric or neonatal
|
|
Measuring intervals:
|
From 2 to 480 min
|
|
INVASIVE BLOOD PRESSURE
|
|
Number of channels:
|
up to 4
|
|
Transducer sensitivity:
|
5.0 μV/V/mmHg
|
|
Range:
|
-40 to 300 mmHg
|
|
Accuracy:
|
± 1 mmHg
|
|
|
|
|
CARDIAC OUTPUT
|
|
Method:
|
Thermodilution
|
|
Range:
|
0.1-20 l/min
|
|
Resolution:
|
0.1 l/min
|
|
Accuracy
|
± 0,1 l/min
|
|
Display:
|
Cardiac output, cardiac index, blood and injectate temperatures
|
|
EtCO2 (mainstream and sidestream)
|
|
Method:
|
Nondispersive IR absorption
|
|
Range:
|
0-150 mm Hg
|
|
Accuracy:
|
± 2 mm Hg (0-40 mm Hg )
|
|
Respiration rate range:
|
0-150 1/min
|
|
MULTI-GAS MODULE
|
|
Method:
|
Infrared absorption
|
|
Gas:
|
CO2 , N2O, O2 , Hal, Iso, Des, Enf, Sev
|
|
Oxygen sensor:
|
galvanic or paramagnetic
|
|
Range:
|
O2 0 -100%
|
|
|
CO2 0-15%
|
|
|
N2O 0-100%
|
|
|
Hal, Iso, Enf 0-8%
|
|
|
Sev 0-10%
|
|
|
Des 0-20%
|
|
BIS Monitoring
|
|
Method:
|
EEG complex processing
|
|
Bispectral Index (BIS):
|
0 -100
|
|
Signal Quality Index (SQI):
|
0 -100%
|
|
Impedance measurement range:
|
0 - 999 kOhm
|
|
Bandwidth:
|
0,25 -100 Hz
|
|
EEG channel
|
|
Channels:
|
2
|
|
Bandwidth:
|
0,25 -100 Hz
|
|
Noise level:
|
< 0,3 μV
|
|
Impedance measurement range:
|
0 - 999 kOhm
|
|
Electrode-to-skin impedances are continuously measured
|
|
RECORDER
|
|
Paper wide:
|
58 mm
|
|
Speed:
|
12.5; 25; 50 mm/s
|
|
Formats:
|
Waveforms, graphs and tables
|
|
Trace:
|
2 or 3
|
|
|
|
Internal battery:
|
Rechargeable, 4 h operation
|
|
Output:
|
LAN Ethenet, WLAN WiFi. USB, RS232, Memory Card, VGA, HDMI, Sync Def,
Sync IABP
|
|
Dimensions:
|
370x350x150 mm (WxHxD)
|
|
Weight:
|
4.2 kg (with gas module and battery)
|
|
DISPLAY
|
|
Size:
|
12.1'' / 30.7 cm diagonal
|
|
Type:
|
bright colour TFT
|
|
Resolution:
|
800x600 dots
|
|
Number of traces:
|
up to 10, user selectable
|
|
ECG
|
|
Leads:
|
I, II, III, aVR, aVL, aVF, V1-V6
|
|
Sweep Speed:
|
6.25; 12.5; 25 и 50 mm/s
|
|
Sensitivity:
Arrhythmia analysis
|
5; 10; 20 mm/mV
|
|
|
|
|
Defibrillator protection
|
|
Pacemaker detection
|
|
|
|
|
|
|
|
|
|
HEART RATE
|
|
Range:
|
15 -350 BPM
|
|
Resolution:
|
1 BPM
|
|
Accuracy:
|
± 1 BPM
|
|
|
|
|
|
|
|
SpO2
|
|
Range:
|
1 -100%
|
|
Resolution:
|
1%
|
|
Accuracy:
|
± 2% (70-100%) 3% (40-70%)
|
|
Pulse rate range:
|
15 - 350 BPM
|
|
Probes:
|
Adult, neonatal
|
|
Accuracy:
|
± 2 BPM
|
|
TEMPERATURE
|
|
Number of channels:
|
1 or 2
|
|
Range:
|
0 - 45°C
|
|
Accuracy:
|
± 0.1°C (30-42 C)
|
|
Probes:
|
YSI 400 (Rectal, skin)
|
|
RESPIRATION RATE
|
|
Method:
|
Impedance
|
|
Range:
|
0-150 1/min
|
|
Accuracy:
|
± 1/min
|
|
Apnea time interval
|
Yes, user selectable
|
|
NIBP
|
|
Method:
|
Oscillometric
|
|
Range:
|
10 - 280 mmHg (adult), 10 - 140 mmHg (neonatal)
|
|
Modes:
|
Manual, automatic, STAT
|
|
Cuff:
|
Adult, pediatric or neonatal
|
|
Measuring intervals:
|
From 2 to 480 min
|
|
INVASIVE BLOOD PRESSURE
|
|
Number of channels:
|
up to 4
|
|
Transducer sensitivity:
|
5.0 μV/V/mmHg
|
|
Range:
|
-40 to 300 mmHg
|
|
Accuracy:
|
± 1 mmHg
|
|
|
|
|
CARDIAC OUTPUT
|
|
Method:
|
Thermodilution
|
|
Range:
|
0.1-20 l/min
|
|
Resolution:
|
0.1 l/min
|
|
Accuracy
|
± 0,1 l/min
|
|
Display:
|
Cardiac output, cardiac index, blood and injectate temperatures
|
|
EtCO2 (mainstream and sidestream)
|
|
Method:
|
Nondispersive IR absorption
|
|
Range:
|
0-150 mm Hg
|
|
Accuracy:
|
± 2 mm Hg (0-40 mm Hg )
|
|
Respiration rate range:
|
0-150 1/min
|
|
MULTI-GAS MODULE
|
|
Method:
|
Infrared absorption
|
|
Gas:
|
CO2 , N2O, O2 , Hal, Iso, Des, Enf, Sev
|
|
Oxygen sensor:
|
galvanic or paramagnetic
|
|
Range:
|
O2 0 -100%
|
|
|
CO2 0-25%
|
|
|
N2O 0-100%
|
|
|
Hal, Iso 0-8%
|
|
|
Enf, Sev 0-10%
|
|
|
Des 0-20%
|
|
BIS Monitoring
|
|
Method:
|
EEG complex processing
|
|
Bispectral Index (BIS):
|
0 -100
|
|
Signal Quality Index (SQI):
|
0 -100%
|
|
Impedance measurement range:
|
0 - 999 kOhm
|
|
Bandwidth:
|
0,25 -100 Hz
|
|
EEG channel
|
|
Channels:
|
2
|
|
Bandwidth:
|
0,25 -100 Hz
|
|
Noise level:
|
< 0,3 μV
|
|
Impedance measurement range:
|
0 - 999 kOhm
|
|
Electrode-to-skin impedances are continuously measured
|
|
RECORDER
|
|
Paper wide:
|
58 mm
|
|
Speed:
|
12.5; 25; 50 mm/s
|
|
Formats:
|
Waveforms, graphs and tables
|
|
Trace:
|
2 or 3
|
|
|
|
Internal battery:
|
Rechargeable, 4 h operation
|
|
Output:
|
LAN Ethenet, WLAN WiFi. USB, RS232, Memory Card, VGA, HDMI, Sync Def,
Sync IABP
|
|
Dimensions:
|
370x350x150 mm (WxHxD)
|
|
Weight:
|
4.2 kg (with gas module and battery)
|
|