Patient Monitor UM-500-7"
UM-500-7” is a multi-functional patient monitor designed to provide continuous monitoring of patient’s vital signs both in hospital and during transportation. Wide range of functions, light weight, compact dimensions and multipurpose mounting system make it a unique device for emergency care and patient transportation in ambulance.
Patient Monitor UM-500-7” is a light-weight, portable device with battery capacity up to 5 hours of operation.
Being mobile, Patient Monitor UM-500-7” allows monitoring of a patient, with medical staff being continuously informed of the changes in general condition of a patient during the treatment. It enables to assess patient's status, treatment efficiency and to make a treatment correction.
Monitored parameters: Heart Rate, ECG, SpO2, Respiration Rate, NIBP, IBP, Temperature, Inspired/Expired СО2.
- • Color 7” display;
• User-friendly touch screen interface;
- • Simultaneous display of up to 6 waveforms;
- • 2 modes of numerics visualization (Standard, Large Numbers);
- • Built-in thermal printer;
- • Multilevel visual and audible alarm of all monitored parameters;
- • Trends of all monitored parameters (up to 96 hours);
- • Saving ECG segments to the non-volatile memory;
- • Arrhythmia analysis;
- • Artifacts protection system;
- • Different mounting solutions.
|
Display
|
|
Size:
|
7” diagonal
|
|
Type:
|
Bright color TFT
|
|
Resolution:
|
800x600 dots
|
|
Number of traces:
|
Up to 6 (ECG, respirogram, photoplethysmogram, CO2 waveform, blood pressure waveforms)
|
|
ECG
|
|
Leads:
|
I, II, III, aVR, aVL, aVF, V1-V6
|
|
Sweep speed:
|
6.25; 12.5; 25 and 50 mm/sec
|
|
Sensitivity:
|
5;10;20 mm/mV
|
|
Defibrillator and coagulator protection Pacemaker detection, arrhythmia analysis
|
|
|
|
Heart rate
|
|
Range:
|
15 - 350 BPM
|
|
Accuracy:
|
± 1 BPM
|
|
Resolution:
|
1 BPM |
|
|
|
SpO2
|
|
Range:
|
1 - 100%
|
|
Accuracy:
|
± 2% (70 - 100%), ±3% (40-70%)
|
|
Pulse rate range:
|
15 - 350 BPM
|
|
Perfusion index:
|
0.02 - 20%
|
|
Signal quality index:
|
0 - 100%
|
|
Accuracy:
|
± 2 BPM
|
|
Resolution:
|
1%
|
|
Probes:
|
Adult, neonatal
|
|
|
|
Temperature
|
|
Number of channels:
|
1 or 2
|
|
Range:
|
0 - 45°C
|
|
Accuracy:
|
± 0.1°C (30-42 C)
|
|
Probes:
|
YSI 400 (skin, rectal)
|
|
Respiration rate
|
|
Method:
|
impedance
|
|
Range:
|
0 – 150 1/min
|
|
Accuracy:
|
± 1/min
|
|
Apnea time interval
|
Yes, user selectable
|
|
NIBP (systolic, diastolic and mean)
|
|
Method:
|
oscillometric
|
|
Range:
|
adult: 10 - 280 mmHg
neonatal: 10 - 140 mmHg
|
|
Cuff:
|
Adult, pediatric or neonatal
|
|
Mode:
|
manual, automatic, STAT, Venous Puncture
|
|
Measuring intervals:
|
From 2 to 480 mi
|
|
Invasive Blood Pressure
|
|
Number of channels:
|
2
|
|
Range:
|
-40 to – 300 mmHg
|
|
Accuracy:
|
± 1 mmHg
|
|
Transducer sensitivity:
|
5.0 µV/V/mmHg
|
|
|
|
|
|
|
|
|
|
|
|
|
|
СО2 (mainstream and sidestream)
|
|
Method:
|
IR absorption
|
|
Range:
|
0 - 150 mmHg
|
|
Accuracy:
|
± 2 mmHg (within range: 0 - 40 mmHg)
|
|
Respiration rate range:
|
0 - 150 1/min
|
|
|
Power supply:
|
- AC 220 V, 50 Hz; - Internal battery(5 h operation);
|
|
Output:
|
LAN Ethernet, WLAN Wi-Fi
|
|
Dimensions:
|
200х130х60 mm
|
|
Weight:
|
1.5 kg (battery included)
|
|