UM 300 Patient Monitor
New multifunctional monitor with 12 '' display, gas module, ECG analysis and enhanced network capacity
Patient Monitors UM 300 are essential for surgeries, anesthesiology departments, intensive care units, maternity wards and patient care during transport
A NEW GENERATION OF PORTABLE PATIENT MONITOR
UM 300 is a new multi-parameter portable patient monitor with high resolution color display and multi-gas module. UM 300 is ideal for operating rooms, intensive care units, recovery rooms and patient care during transport. Monitor can be connected to the Central Station to make monitoring information available throughout the hospital.
- • Unique networking capacity which allows viewing hospital network data, digital images, lab results, medication guidelines etc;
- • High brightness, wide viewing angle, colour 12.1'' display;
- • Expanded monitoring capabilities: ECG, HR, pulse oximetry, NIBP, respiration rate, temperature, invasive blood pressure, cardiac output, CO2, N2O, O2 and 5 anesthetic agents;
- • Simultaneous display of up to 8 real-time waveforms;
- • Advanced digital signal processing;
- • Alarm supervision of all vital signs;
- • Multi-level alarm management;
- • 12-lead ECG;
- • Arrhythmia and ST segment analysis;
- • Heart rate variability analysis;
- • Up to 96 hours trend for all measured values;
- • 60 seconds full-disclosure waveforms review;
- • Up to 4 hours of internal battery operation;
- • Drug dose and infusion rate calculator.
| DISPLAY |
| Size: |
12.1'' / 30.7 cm diagonal |
| Type: |
bright colour TFT |
| Resolution: |
800x600 dots |
| Number of traces: |
up to 8, user selectable
|
| ECG |
| Leads: |
I, II, III, aVR, aVL, aVF, V1-V6
|
| Sweep Speed: |
6.25; 12.5; 25 и 50 mm/s |
| Sensitivity: |
5; 10; 20 mm/mV |
| Waveform scale range |
х0.25; х0.5; х1; х2, automatic setting |
| Defibrillator protection |
| Pacemaker detection |
| Filter Mode |
| Diagnostic > 90 dB, 0,05 - 100 Hz |
| Monitor > 105 dB, 0,05 -100 Hz |
| Syrgery > 105 dB, 1 -20 Hz |
| HEART RATE |
| Range: |
0 -350 BPM |
| Resolution: |
1 BPM |
| Accuracy: |
± 1 BPM |
Low alarm level
|
15 BPM |
| High alarm level |
300 BPM |
| SpO2 |
| Range: |
1 -100% |
| Resolution: |
1% |
| Accuracy: |
± 2% (70-100%) |
Pulse rate range:
|
0 - 350 BPM |
| Probes: |
Adult, neonatal |
| Accuracy: |
± 2 BPM |
| TEMPERATURE |
| Number of channels: |
2 |
| Range: |
0 - 50°C |
| Accuracy: |
± 0.1°C
|
| Probes: |
YSI 400 (Rectal, skin) |
| RESPIRATION RATE |
Method:
|
Impedance |
Range:
|
3 - 200 1/min |
| Accuracy: |
± 1/min |
Apnea time interval
|
10 - 40 sec |
| NIBP |
Method:
|
Oscillometric |
Range:
|
10 - 300 mmHg (adult), 10 - 140 mmHg (neonatal)
|
| Modes: |
Manual, automatic, STAT |
| Cuff: |
Adult, pediatric or neonatal" |
| Measuring intervals: |
From 2 to 480 min |
| INVASIVE BLOOD PRESSURE |
| Number of channels: |
up to 4 |
| Transducer sensitivity: |
5.0 μV/V/mmHg |
| Range: |
-40 to 300 mmHg |
| Accuracy: |
± 1 mmHg |
| Sensors: |
Different type of transducers |
| CARDIAC OUTPUT |
Method:
|
Thermodilution |
| Range: |
0.1-20 l/min |
| Resolution: |
0.1 l/min |
| Accuracy |
± 1 l/min |
| Display: |
Cardiac output, cardiac index, blood and injectate temperatures |
| EtCO2 (mainstream and sidestream) |
| Method: |
Nondispersive IR absorption |
| Range: |
0-150 mm Hg |
| Accuracy: |
± 2 mm Hg (0-40 mm Hg ) |
| Respiration rate range: |
0-150 1/min |
| MULTI-GAS MODULE |
| Method: |
Infrared absorption |
| Gas: |
CO2 , N2O, O2 , Hal, Iso, Des, Enf, Sev |
|
|
| Range: |
O2 0 -100% |
|
CO2 0-25% |
|
N2O 0-100% |
|
Hal, Iso 0-8% |
|
Enf, Sev 0-10% |
|
Des 0-20% |
| RECORDER |
| Paper wide: |
50 mm |
| Speed: |
12.5; 25; 50 mm/s |
| Formats: |
Waveforms, graphs and tables |
| Trace: |
2 or 3 |
|
| Internal battery: |
Rechargeable, 4 h operation |
| Output: |
LAN Ethenet, WLAN WiFi.
|
| Dimensions: |
370x350x150 mm (WxHxD) |
| Weight: |
4.2 kg (with gas module and battery) |
|