UM 300
A NEW GENERATION OF PORTABLE PATIENT MONITOR.
UM 300 is a new multi-parameter portable patient monitor with high resolution color display and multi-gas module. UM 300 is ideal for operating rooms, intensive care units, recovery rooms and patient care during transport. Monitor can be connected to the Central Station to make monitoring information available throughout the hospital.
Features :
- Unique networking capacity which allows viewing hospital network data, digital images, lab results, medication guidelines etc;
- High brightness, wide viewing angle, color 12.1'' display;
- Expanded monitoring capabilities: ECG, HR, Pulse Oximetry, NIBP, Respiration Rate, Temperature, Invasive Blood Pressure, Cardiac Output, CO2, N2O, O2 and 5 Anesthetic Agents;
- Simultaneous display of up to 8 real-time waveforms;
- Advanced Digital Signal Processing;
- Alarm supervision of all vital signs;
- Multi-level alarm management;
- 12-lead ECG;
- Arrhythmia and ST segment analysis;
- Heart Rate Variability analysis;
- Up to 72 hours trend for all measured values;
- 60 seconds full-disclosure waveforms review;
- Up to 4 hours of internal battery operation;
- Drug dose and infusion rate calculator.
Specifications:
| DISPLAY |
|
Size: |
12.1’’ diagonal |
|
Type: |
Bright colour TFT |
|
Resolution: |
800x600 dots |
|
Number of Traces: |
up to 8, user selectable |
| ECG |
|
Leads: |
I, II, III, aVR, aVL, aVF, V with 5 lead cable I, II, III, aVR, aVL, aVF, V1-V6 with 10 lead cable |
|
Sweep Speed: |
6,25;12,5; 25 and 50 mm/s |
|
Sensitivity: |
5; 10; 20 mm/mV |
|
Sampling Frequency: |
1000 Hz |
|
Defibrillator protection, Pacemaker detection |
| HEART RATE |
|
Range: |
15-350 BPM |
|
Resolution: |
1 BPM |
|
Accuracy: |
± 1 BPM |
| SPO2 |
|
Range: |
0-100% |
|
Resolution: |
1% |
|
Accuracy: |
± 2% (70-99%) ± 3% (40-70%) |
|
Probes: |
adult, neonatal |
|
Pulse rate range: |
20-300 BPM |
|
Accuracy: |
± 1 BPM |
| NIBP |
|
Method: |
Oscillometric |
|
Range: |
0-300 mm Hg |
|
Modes: |
Manual, Automatic, STAT |
|
Cuff: |
Adult, Pediatric or Neonatal |
|
Measuring Intervals: |
from 2 to 480 min |
| RESPIRATION RATE |
|
Method: |
impedance |
|
Range: |
0-150 1/min |
|
Accuracy: |
± 1/min |
|
Apnea: |
Yes, user selectable |
| TEMPERATURE |
|
Number of Channels: |
2 |
|
Range: |
0-45 °C |
|
Resolution: |
0,1 °C |
|
Accuracy: |
± 0,1 °C (30-42 °C) |
|
Probes: |
rectal, skin |
|
INVASIVE BLOOD PRESSURE |
|
Number of Channels: |
up to 4 |
|
Transducer sensitivity: |
5.0 mV/V/mm Hg |
|
Range: |
-30 to 300 mm Hg |
|
Accuracy: |
± 1 mm Hg |
|
Sensors: |
Different type of transducers |
|
CARDIAC OUTPUT |
|
Method: |
Thermodilution |
|
Range: |
0,1-20 l/min |
|
Resolution: |
0,1 l/min |
|
Accuracy: |
± 0,1 l/min |
|
Display: |
Cardiac output, cardiac index, blood and injectate temperatures |
|
EtCO2 – Mainstream and Sidestream |
|
Method: |
Nondispersive IR Absorption |
|
Range: |
0-150 mm Hg |
|
Accuracy: |
± 2 mm Hg (0-40 mm Hg ) |
|
Respiration rate range: |
3-150 1/min |
|
MULTI-GAS MODULE |
| Method |
Infrared Absorption |
| Gas |
CO 2 , N 2 O, O 2 , Hal, Iso, Des, Enf, Sev |
| Range |
O 2 5-100% CO 2 0-10% N 2 O 0-100% Hal, Iso 0-8% Enf, Sev 0-10% Des 0-20% |
|
RECORDER |
|
Trace: |
2 or 3 |
|
Paper wide: |
58 mm |
|
Speed: |
12.5; 25; 50 mm/s |
|
Formats: |
waveforms, graphs and tables |
| _______________________________________________________________ |
|
Output: |
LAN Ethernet; WLAN WiFi; RS 232 |
|
Internal Battery: |
Rechargeable, 4 h operation |
|
Dimensions: |
370x350x150 mm(WxHxD) |
|
Weight: |
4.2 kg (with Gas Module and Battery) |
|